Tuesday, March 7, 2023

FLUKE INTELLITONE PRO LAN QUICK REFERENCE MANUAL Pdf Download | ManualsLib

Looking for:

Fluke intellitone pro 200 manual 













































    ❿  

Fluke intellitone pro 200 manual.Your Download Is Ready



 

All product names are trademarks of their respective companies. Previous Page. Next Page. Page 2 90 days, unless otherwise stated. Page 4 Testing for Continuity The IT toner detects telephone and Ethernet service, indicates polarity and active line numbers on voice circuits, and indicates active pair number on Ethernet circuits. Page 7: Registration To www. Inspect the cases and test leads Table 1 describes the international electrical symbols used for damage before use.

The probe turns off automatically after 1 hour of inactivity. Page 11 RJ11 and RJ45 connectors. Use the following: continuity test page 15 to check for shorts on Connect the IT toner to a jack or punch-down coax and non-terminated cables.

Locating and Isolating Cables The in the sequence. See text. Validating Cable Maps Note This test requires power from the Central Office.

Turn off the toner. Line 1 Line 2 Connect the toner to the circuit as shown in Figure 3. Green: service on 3, 6 Connect the toner to the circuit as shown in Figure 4. If you are testing a circuit, verify that it is not powered. Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price.

Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid FOB destination.

Fluke Networks assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid FOB destination. If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the work.

Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges FOB Shipping point. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer.

If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Overview of Features The toner also lets you validate voice and data services. The toner and probe feature both digital and analog toning and detection.

The digital IntelliTone tone is primarily used on data cables, and on active networks. In these environments, the digital signal eliminates cable misidentification due to signal bleed and radiated or ambient noise. The analog tone is primarily used on voice cables, and on bare wire. The SmartTone analog technology will. This makes exact pair identification easy and precise. The IT toner detects telephone and Ethernet service, indicates polarity and active line numbers on voice circuits, and indicates active pair number on Ethernet circuits.

RegistrationRegistering your product with Fluke Networks gives you access to valuable information on product updates, troubleshooting tips, and other support services. To register, fill out the online registration form on the Fluke Networks website at www.

If you do not have Internet access, print the registration form from the CD included with the product. Fill out the form, then mail or fax it to the appropriate address for your country. Contacting Fluke NetworksFor technical support, please contact us via [email protected]. UnpackingThe IT products come with the accessories listed below. If an accessory is damaged or missing, contact the place of purchase immediately. Safety InformationTable 1 describes the international electrical symbols used on the tester and in this manual.

Table 1. International Electrical Symbols. Never use the toner, probe, or test leads if they are damaged. Inspect the cases and test leads for damage before use. Disconnect unused test leads and connectors from the toner when testing telephone circuits. Never open the case except to change the battery; no user-serviceable parts are inside. Turn off the toner or probe and disconnect all test leads before replacing the battery. Use only a 9V battery, properly installed in the case, to power the toner and probe.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Warning: Risk of personal injury. See explanations in the manual. Caution: Risk of damage or destruction to equipment or software.

Warning: Risk of electric shock. This equipment not for connection to public communications networks, such as active telephone systems.

Do not put circuit boards in the garbage. Dispose of circuit boards in accordance with local regulations. Conformit Europenne. WCaution Avoid touching the probe tip to patch panel connections and using the tip to dig into cable bundles.

Doing so regularly may damage the probe tip over time. To avoid unreliable test results, replace the battery as soon as the low battery indication appears. Battery StatusLEDs on the toner and probe light for 1 second at power on to indicate the battery status:.

Auto Power DownThe toner turns off automatically after approximately 2 hours of inactivity. The probe turns off automatically after 1 hour of inactivity. To reactivate the toner or probe, turn the rotary switch to any position except OFF. With the toner set to digital tone mode, the probe can be set to either locate M or isolate N.

Both toning signals are available at all connectors on the toner. Yellow: Battery is marginal. Red: Battery is low. See Battery Life and Replacement on page 16 for more information on the battery. To locate and isolate cables using the digital tone, do the following: 1. Connect the IT toner to a jack or punch-down block as shown in Figure 1. Turn the toners rotary switch to M.

Turn the IT probes rotary switch to M locate. Use the probe to find the general location of the tone at a cable rack, patch panel, or behind a wall. In locating mode, the probes LEDs light up from 1 to 8 as the signal strength increases. The higher the number, the stronger the signal.

Note If you cannot locate the IntelliTone signal on 2-conductor cables, the cable may be shorted. Use the cable map test page 10 to test for shorts on cables with RJ11 and RJ45 connectors. Use the continuity test page 15 to check for shorts on coax and non-terminated cables.

Turn the probes rotary switch to N isolate. Use the probe to isolate the tone source in the cable bundle or at the patch panel. In isolating mode, the probes LEDs light up from 1 to 8 as the signal strength increases. SmartTone is intended for use on dry pairs of wires that are un-terminated at both ends of the run.

It is not intended to be used on live wires with a DC power source e. SmartTone works on many types of wire pairs including twisted pair, house wiring, and coax the shield is one wire and the center conductor is the other wire of the pair.

SmartTone Positive Identification1. The toner red lead must be connected to one of the wires of the pair, and the black lead must be connected to the other wire of the pair. Put the toner and probe in the H position. At the far end of the cable run, place the probe near the wires you are tracing.

Pick the pair that gives the loudest signal in the toner speaker. Short and release the two wires of the pair. If you hear a change in the pattern of the tone, then you have located the target pair of wires.

❿    

 

Fluke intellitone pro 200 manual.Find It | Fluke Networks



    Red: Battery is low. Accessory Test lead set, banana jacks to alligator clips Test lead set, banana jacks to alligator clips with bed of nails Soft carrying case. Подробнее на этой странице The position of the probes rotary switch when the battery is replaced enables or disables shield validation for cable map tests. Use the probe to find the general location of the fluke intellitone pro 200 manual at a cable rack, patch panel, or behind a wall. Table 2. Never use the toner, probe, or test leads if they are damaged. ❿


No comments:

Post a Comment

Download Roxio Toast Titanium 18 for Mac - .Download the Best Toast for Windows Alternative for 10/8/7/Vista/XP

Looking for: Roxio toast for windows free download  Click here to DOWNLOAD       Roxio Toast 17 Has a New Version: Get it Now!.How to c...